Wheel Size |
N/A 15 1/2 x 5BC |
Inlet |
N/A 10 in |
Outlet |
N/A 8 in |
Capacity at 1 Inch (in) Static Pressure |
N/A 2610 ft³/min |
Power at 1 Inch (in) Static Pressure |
N/A 7.10 bhp |
Capacity at 3 Inch (in) Static Pressure |
N/A 2420 ft³/min |
Power at 3 Inch (in) Static Pressure |
N/A 6.50 bhp |
Capacity at 5 Inch (in) Static Pressure |
N/A 2210 ft³/min |
Power at 5 Inch (in) Static Pressure |
N/A 6.00 bhp |
Capacity at 7 Inch (in) Static Pressure |
N/A 1975 ft³/min |
Power at 7 Inch (in) Static Pressure |
N/A 5.50 bhp |
Capacity at 9 Inch (in) Static Pressure |
N/A 1712 ft³/min |
Power at 9 Inch (in) Static Pressure |
N/A 4.95 bhp |
Capacity at 11 Inch (in) Static Pressure |
N/A 1425 ft³/min |
Power at 11 Inch (in) Static Pressure |
N/A 4.10 bhp |
Rotation |
N/A Counterclockwise (CCW) only |
Applications |
N/A These blowers are widely used for exhausting smoke, fumes, and dust where higher pressure is required. Other uses may include food processing, chemical processing, and high pressure cooling and drying. |